A
Rooms are ventilated with a long-lasting, easily maintained Cartridge-type dust collector (shown).
B
Bucket elevator, with rugged PVC-dacron belting, lifts media from floor level to the reclamation system.
C
Media air-wash removes oversized particles and dust from the blast cycle while returning good media to the storage hopper for reuse. Cyclonic media reclaimers replace the air-wash in some recovery systems, such as Empire's PRS.
D
Media is normally stored in a Cylindrical hopper sized to and mounted on the pressure vessel for automatic gravity refills. A higher-capacity, Free-standing hopper can be substituted to lengthen operating cycles when a partial recovery floor is used.
E
A.S.M.E.- approved Pressure vessels offer 6-1/2 or 10 1/2 cubic-foot capacity and a 1-1/4"
pipe string to provide ample air flow when optional second outlet is required. |
F
OSHA-approved, Man-access door is equipped with panic hardware and can be conveniently positioned along either side wall.
G
Electrical controls are installed in NEMA-12 enclosures and pre-wired for easy hookup.
H
Empire gives you a wide range of choices for conveying media including: Screw floors, Vibratory floors, Sweep chutes, Shovel chutes and Pneumatic-recovery troughs.
I Work-access doors provide a large entry for loading parts. Rooms can be equipped with doors at both ends to facilitate in-line parts handling.
J Air-inlet plenums are custom engineered to meet proper cross-draft requirements.
K Fluorescent lighting, protected by clear lexan panels, provides excellent illumination and can be replaced easily from the top of the room. |